Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Arch. med ; 21(1): 85-91, 2021/01/03.
Article in English | LILACS | ID: biblio-1148375

ABSTRACT

Objective: the aim of this study was to verify the reproducibility index of the frequency meter with GPS technology with recording speed of 1Hz in acyclic displacement and intermittent intensity, performed by soccer referees. Materials and methods: it was characterized by a field study with a quantitative trait involving 14 men, aged 20.42 ± 2.78 years, from a barracks in the city of Rio de Janeiro. Polar heart rate monitor with 1Hz GPS model V800 was used. The protocol used was adapted from the FIFA test protocol for soccer referees, so that 10 "shots" of 75m in 15s were accomplished by 25m in 20 of recovery. Testing and retest were applied with 7 days interval and identical protocols: heating, ambiance (4 "shots" following the model of the protocol above) and then the test. Since the circuit covered in the test protocol was 1000 m. Results: a mean of 1002.5 ± 17.12 m was obtained in the test and in the test 1010.83 ± 32.88 m, the coefficients of variation were respectively 1% and 3%. The difference was not significant between the test and the retest (P-value> 0.05), and the intraclass correlation coefficient indicated a moderate association between the measures. Conclusion: therefore, it is suggested that it is acceptable to use a frequency gauge with a recording speed of 1Hz to monitor displacements of soccer referees in acyclic displacement and intermittent intensity..Au


Objetivo: el objetivo de este estudio fue verificar el índice de reproducibilidad del medidor de frecuencia con tecnología GPS con velocidad de grabación de 1Hz en desplazamiento acíclico e intensidad intermitente, realizado por árbitros de fútbol. Materiales y métodos: se caracterizó por un estudio de campo con un rasgo cuantitativo que involucró a 14 hombres, de 20.42 ± 2.78 años, de un cuartel en la ciudad de Río de Janeiro. Se utilizó un monitor de frecuencia cardíaca polar con GPS 1Hz modelo V800. El protocolo utilizado fue adaptado del protocolo de prueba de la FIFA para los árbitros de fútbol, de modo que se lograron 10 "tiros" de 75 m en 15 segundos por 25 m en 20 de recuperación. La prueba y la nueva prueba se aplicaron con un intervalo de 7 días y protocolos idénticos: calentamiento, ambiente (4 "disparos" siguiendo el modelo del protocolo anterior) y luego la prueba. Dado que el circuito cubierto en el protocolo de prueba fue de 1000 m. Resultados: se obtuvo una media de 1002.5 ± 17.12 m en la prueba y en la prueba 1010.83 ± 32.88 m, los coeficientes de variación fueron respectivamente 1% y 3%. La diferencia no fue significativa entre la prueba y la nueva prueba (valor P> 0.05), y el coeficiente de correlación intraclase indicó una asociación moderada entre las medidas. Conclusión: por lo tanto, se sugiere que sea aceptable usar un medidor de frecuencia con una velocidad de grabación de 1Hz para monitorear los desplazamientos de los árbitros de fútbol en desplazamiento acíclico e intensidad intermitente..Au


Subject(s)
Humans , Soccer , Remote Sensors
2.
Arch. med ; 20(2): 331-343, 20200703.
Article in Portuguese | LILACS | ID: biblio-1118851

ABSTRACT

Objetivo: a radiodermite ou radiodermatite é uma reação celular inflamatória desencadeada pela radioterapia, que é uma das alternativas para tratamento de vários tipos de cânceres. O objetivo deste trabalho foi analisar os principais métodos de diagnóstico de radiodermite com uso de ferramentas tecnológicas, quanto a equipamentos utilizados, forma de análise clínica, parâmetros desenvolvidos e produto final. Materiais e métodos: optou-se pela revisão sistemática de caráter exploratório e abordagem qualitativa. A busca por estudos em periódicos internacionais foi realizada no mês de julho de 2019, nas bases de dados MEDLINE e SCOPUS. Foram utilizados os descritores "radiodermatitis" e "acute radiation dermatitis", para a busca. Os critérios de inclusão foram: artigo, escrita em inglês, publicação nos últimos dez anos (01/2009 a 07/2019), e conteúdo relacionado ao diagnóstico de radiodermite causada por radioterapia de aplicação exclusiva. Resultados: esta revisão encontrou estudos sobre as seguintes ferramentas tecnológicas: avaliação citológica, avaliação de fluxo sanguíneo, machine learning, escala fotográfica, imagem térmica, dose de irradiação e espectrofotometria. O uso de imagens fotográficas e térmicas tem se consolidado como ferramenta de diagnóstico importante na área médica. Essas ferramentas tecnológicas têm se mostrado aplicáveis ao diagnóstico da radiodermite, com seu efeito potencializado por processamento digital de imagens e algoritmos de inteligência artificial. Conclusões: a análise aqui descrita demonstra a necessidade de desenvolvimento tecnológico para delineamento e padronização do processo de diagnóstico da radiodermite, o que permitiria tratamento precoce e manutenção do engajamento do indivíduo na terapia antineoplásica..Au


Objective: radiodermatitis or radiodermatitis is an inflammatory cell reaction triggered by radiotherapy, which is one of the alternatives for the treatment of various types of cancers. The objective of this work was to analyze the main diagnostic methods of radiodermatitis with the use of technological tools, regarding the equipment used, the form of clinical analysis, parameters developed and the final product. Materials and methods: a systematic review with an exploratory nature and a qualitative approach was performed. The search for studies in international journals was carried out in July 2019, in the MEDLINE and SCOPUS databases. The descriptors "radiodermatitis" and "acute radiation dermatitis" were used for the search. The inclusion criteria were: article, written in English, published in the last ten years (01/2009 to 07/2019), and content related to the diagnosis of radiodermatitis caused by radiotherapy of exclusive application. Results: This review found studies on the following technological tools:cytological assessment, blood flow assessment, machine learning, photographic scale, thermal image, irradiation dose, and spectrophotometry. The use of photographic and thermal images has been consolidated as an important diagnostic tool in the medical field. These technological tools have been shown to be applicable to the diagnosis of radiodermatitis, with its effect enhanced by digital image processing and artificial intelligence algorithms.Conclusions: The analysis described here demonstrates the need for technological development to outline and standardize the radiodermatitis diagnostic process, which would allow early treatment and maintenance of the individual's engagement in antineoplastic therapy..Au


Subject(s)
Radiodermatitis , Diagnosis
3.
Arch. med ; 20(1): 33-39, 2020-01-18.
Article in English | LILACS | ID: biblio-1053184

ABSTRACT

Objective: analyze the agreement of the V̇O2max values estimated by American College of Sports Medicine and Foster equations with direct measure gas analyze in young Brazilian males. The maximal oxygen uptake, as a health indicator and mortality predictor, can be assessed in different ways. The gold standard comprises the direct measurement of exhaled gases, which entails high cost. A more conveniently form can be estimation equations. Materials and methods: this study assessed VO2max of 41 young Brazilian males (21.4 ±2.2 years) by cardiopulmonary exercise test in a treadmill ergometer with a ramp protocol. Bland and Altman analysis was performed to verify the agreement between V̇ O2max measured and estimated values by ACSM and Foster equations. Results:the measured VO2max was 52.3 ± 4.9 ml.kg-1.min-1. The difference between the measured V̇O2max and the estimated V̇ O2max by the ACSM equation (9.40±3.67) was approximately 7.5 times greater than the difference between the measured V̇O2max and estimated V̇O2max by Foster's equation (1.25±3.46). Bland Altman graphics shows that only ACSM equation had mean differences that were significantly different from the measured value. Conclusions: the ACSM equation showed not appropriate for during treadmill stress testing young adults in a ramp protocol and Foster equation seems to be a more accurate estimator of V̇O2max for this population, besides showed a bias along the aerobic capacity, trending to overestimates and underestimates V̇O2max of least and most fit people, respectively..(AU)


Objetivo: analizar la concordancia de los valores de VO2max estimados por las ecuaciones del Colegio Americano de Medicina del Deporte y de Foster con el análisis de gases de medida directa en varones brasileños jóvenes. el consumo máximo de oxigeno, como un indicador de salud y predictor de mortalidad, se puede evaluar de diferentes maneras. El estándar de oro comprende la medición directa de los gases exhalados, lo que implica un alto costo. Una forma más conveniente puede ser las ecuaciones de estimación. Materiales y métodos: este estudio evaluó el VO2máx de 41 hombres brasileños jóvenes (21,4 ± 2,2 años) mediante una prueba de ejercicio cardiopulmonar en un ergómetro en cinta ergométrica con un protocolo de rampa. El análisis de Bland y Altman se realizó para verificar la concordancia entre V̇O2max medido y valores estimados por las ecuaciones del ACSM y de Foster. Resultados: el VO2max medido fue de 52,3 ± 4,9 ml.kg-1.min-1. La diferencia entre el V̇O2max medido y el VO2max estimado por la ecuación ACSM (9,40 ± 3,67) fue aproximadamente 7.5 veces mayor que la diferencia entre el VO2max medido y el VO2max estimado por la ecuación de Foster (1,25 ± 3,46). Los gráficos de Bland Altman muestran que solo la ecuación de ACSM tenía diferencias estadísticas del valor medido. Conclusiones: la ecuación ACSM no fue adecuada durante la prueba de ejercicio en cinta de correr en adultos jóvenes en un protocolo de rampa y la ecuación de Foster parece ser un estimador más preciso de VO2max para esta población, además mostró un sesgo a lo largo de la capacidad aeróbica, con tendencia a sobreestimar y subestimar VO2 máx. de personas menos y más en preparadas, respectivamente..(AU)


Subject(s)
Male , Oxygen Consumption , Exercise
4.
Article in Portuguese, English | LILACS | ID: lil-721783

ABSTRACT

O objetivo deste estudo foi analisar a incidência e o tempo dos afastamentos ligados especificamente às causas psicológicas entre profissionais de enfermagem. Além disso, procurou identificar fatores de risco para os afastamentos e sugerir ações que possam mitigar os problemas encontrados. Métodos: Foi feito um estudo ecológico, retrospectivo, no maior hospital público de Curitiba- PR, com dados de 3.692 profissionais de enfermagem (2.294 auxiliares de enfermagem, 590 técnicos de enfermagem e 808 enfermeiros), de janeiro de 2007 a setembro de 2010. Realizou-se uma pesquisa exploratória de revisão para formar o arcabouço teórico deste estudo. Foram identificadas as incidências anuais de cada tipo de afastamento por causas psicológicas, entre os profissionais de enfermagem. Resultados: Verificou-se que a principal causa de afastamentos foram os episódios depressivos (F32), com 784 afastamentos. Quanto ao tempo de afastamento, a causa que por mais tempo afastou os enfermeiros (média de 40,62 dias) foi o transtorno afetivo bipolar (F31). Os auxiliares e os técnicos em enfermagem se afastaram devido ao transtorno depressivo recorrente (F33), em média, por 40,47 e 54,33 dias, respectivamente. Conclusão: Houve uma alta incidência dos episódios depressivos e o tempo médio de afastamento devido a causas psicológicas foi superior a 30 dias, o que aponta a necessidade de investimentos na prevenção e no cuidado à saúde dos profissionais de enfermagem...


To analyze the incidence and the length of periods off work specifically linked to psychological causes among nursing professionals. Furthermore, the study tried to identify risk factors for the work leaves and suggest actions that can mitigate the problems encountered. Methods: This was a retrospective, ecological study, in the largest public hospital of Curitiba-PR, with data from 3,692 nurses (2,294 auxiliary nurses, 590 nursing technicians and 808 nurses) from January 2007 to September 2010. An exploratory review was performed to form the theoretical basis of this study. The annual incidences for each type of work leave due to psychological causes were identified, among the nursing professionals. Results: It was found that the main cause of absenteeism were depressive episodes (F32), with 784 leaves. As for the length of time, the cause for longer periods off among nurses (40.62 days on average) was the bipolar affective disorder (F31). Nursing assistants and technicians were away from work due to recurrent depressive disorder (F33) on average for 40.47 days and 54.33 days, respectively. Conclusion: There was a high incidence of depressive episodes and the mean duration of absenteeism due to psychological causes was over 30 days, pointing to the need of investments in prevention and in healthcare for nursing professionals...


El objetivo del estudio fue analizar la incidencia y el tiempo de baja laboral de los profesionales de enfermería relacionados específicamente a causas psicológicas. Además de eso, se buscó identificar factores de riesgo para las bajas y sugerir acciones que puedan suavizar los problemas encontrados. Métodos: Fue realizado un estudio ecológicoy retrospectivo en el hospital público más grande de Curitiba- PR, con datos de 3.692 profesionales de enfermería (2.294 auxiliares de enfermería, 590 técnicos de enfermería y 808 enfermeros), de enero de 2007 a septiembre de 2010. Se realizó una investigación exploratoria de revisión para formar el modelo teórico de este estudio. Las incidencias anuales de cada tipo de baja por causas psicológicas fueron identificadas entre los profesionales de enfermería. Resultados: Se verificó que la principal causa de bajas fueron los episodios de depresión (F32) con 784 bajas. Respecto al tiempo de baja, la causa que más afectó a los enfermeros (media de 40,62 días) fue el trastorno afectivo bipolar (F31). Los auxiliares y los técnicos de enfermería tuvieron el alta por trastorno depresivo recurrente (F33), en media de 40,47 y 54,33 días, respectivamente. Conclusión: Hubo una incidência elevada de episodios depresivos y el tiempo medio de baja por causas psicológicas fue de más de 30 días, lo que sugiere La necesidad de inversiones para la prevención y el cuidado de La salud de profesionales de enfermería...


Subject(s)
Humans , Absenteeism , Mental Health , Occupational Diseases
SELECTION OF CITATIONS
SEARCH DETAIL